Delete zm_update-1.37.multistream.sql asit has been merged to 1.37.12

This commit is contained in:
Isaac Connor 2022-03-04 12:09:41 -05:00
parent 1fb42d0b77
commit 69856f2b8c
1 changed files with 0 additions and 66 deletions

View File

@ -1,66 +0,0 @@
SET @s = (SELECT IF(
(SELECT COUNT(*) FROM INFORMATION_SCHEMA.COLUMNS WHERE table_schema = DATABASE()
AND table_name = 'Monitors'
AND column_name = 'Capturing'
) > 0,
"SELECT 'Column Capturing already exists in Monitors'",
"ALTER TABLE `Monitors` ADD `Capturing` enum('None','Ondemand', 'Always') NOT NULL default 'Always' AFTER `Function`"
));
PREPARE stmt FROM @s;
EXECUTE stmt;
UPDATE `Monitors` SET `Capturing` = 'None' WHERE `Function` = 'None';
SET @s = (SELECT IF(
(SELECT COUNT(*) FROM INFORMATION_SCHEMA.COLUMNS WHERE table_schema = DATABASE()
AND table_name = 'Monitors'
AND column_name = 'Analysing'
) > 0,
"SELECT 'Column Analysing already exists in Monitors'",
"ALTER TABLE `Monitors` ADD `Analysing` enum('None','Always') NOT NULL default 'Always'"
));
PREPARE stmt FROM @s;
EXECUTE stmt;
UPDATE `Monitors` SET `Analysing` = 'None' WHERE `Function` = 'Record' OR `Function` = 'Nodect';
SET @s = (SELECT IF(
(SELECT COUNT(*) FROM INFORMATION_SCHEMA.COLUMNS WHERE table_schema = DATABASE()
AND table_name = 'Monitors'
AND column_name = 'AnalysisSource'
) > 0,
"SELECT 'Column AnalysisSource already exists in Monitors'",
"ALTER TABLE `Monitors` ADD `AnalysisSource` enum('Primary','Secondary') NOT NULL DEFAULT 'Primary' AFTER `Analysing`"
));
PREPARE stmt FROM @s;
EXECUTE stmt;
SET @s = (SELECT IF(
(SELECT COUNT(*) FROM INFORMATION_SCHEMA.COLUMNS WHERE table_schema = DATABASE()
AND table_name = 'Monitors'
AND column_name = 'Recording'
) > 0,
"SELECT 'Column Recording already exists in Monitors'",
"ALTER TABLE `Monitors` ADD `Recording` enum('None', 'OnMotion', 'Always') NOT NULL default 'Always'"
));
PREPARE stmt FROM @s;
EXECUTE stmt;
UPDATE `Monitors` SET `Recording` = 'None' WHERE `Function` = 'Monitor';
UPDATE `Monitors` SET `Recording` = 'OnMotion' WHERE `Function` = 'Modect';
SET @s = (SELECT IF(
(SELECT COUNT(*) FROM INFORMATION_SCHEMA.COLUMNS WHERE table_schema = DATABASE()
AND table_name = 'Monitors'
AND column_name = 'RecordingSource'
) > 0,
"SELECT 'Column RecordingSource already exists in Monitors'",
"ALTER TABLE `Monitors` ADD `RecordingSource` enum('Primary','Secondary','Both') NOT NULL DEFAULT 'Primary' AFTER `RecordAudio`"
));
PREPARE stmt FROM @s;
EXECUTE stmt;