Merge pull request #938 from onlyjob/zmtrigger
zmtrigger: POD documentation
This commit is contained in:
commit
a53ee60590
|
@ -28,7 +28,82 @@ zmtrigger.pl - ZoneMinder External Trigger Script
|
|||
=head1 DESCRIPTION
|
||||
|
||||
This script is used to trigger and cancel alarms from external connections
|
||||
using an arbitrary text based format
|
||||
using an arbitrary text based format.
|
||||
|
||||
This script offers generic solution to external triggering of alarms. It
|
||||
can handle external connections via either internet socket, unix socket or
|
||||
file/device interfaces. You can either use it 'as is' if you can interface
|
||||
with the existing format, or override connections and channels to customise
|
||||
it to your needs.
|
||||
|
||||
If enabled by the OPT_TRIGGERS option, Zoneminder service start
|
||||
zmtrigger.pl which listens for control messages on TCP port 6802.
|
||||
|
||||
=head1 TRIGGER MESSAGE FORMAT
|
||||
|
||||
B<id>|B<action>|B<score>|B<cause>|B<text>|B<showtext>
|
||||
|
||||
=over 4
|
||||
|
||||
=item B<id>
|
||||
|
||||
is the id number or name of the ZM monitor.
|
||||
|
||||
=item B<action>
|
||||
|
||||
Valid actions are 'on', 'off', 'cancel' or 'show' where
|
||||
'on' forces an alarm condition on;
|
||||
'off' forces an alarm condition off;
|
||||
'cancel' negates the previous 'on' or 'off'.
|
||||
|
||||
The 'show' action merely updates some auxiliary text which can optionally
|
||||
be displayed in the images captured by the monitor. Ordinarily you would
|
||||
use 'on' and 'cancel', 'off' would tend to be used to suppress motion
|
||||
based events. Additionally 'on' and 'off' can take an additional time
|
||||
offset, e.g. on+20 which automatically 'cancel's the previous action
|
||||
after that number of seconds.
|
||||
|
||||
=item B<score>
|
||||
|
||||
is the score given to the alarm, usually to indicate it's
|
||||
importance. For 'on' triggers it should be non-zero, otherwise it should
|
||||
be zero.
|
||||
|
||||
=item B<cause>
|
||||
|
||||
is a 32 char max string indicating the reason for, or source of
|
||||
the alarm e.g. 'Relay 1 open'. This is saved in the 'Cause' field of the
|
||||
event. Ignored for 'off' or 'cancel' messages.
|
||||
|
||||
=item B<text>
|
||||
|
||||
is a 256 char max additional info field, which is saved in the
|
||||
'Description' field of an event. Ignored for 'off' or 'cancel' messages.
|
||||
|
||||
=item B<showtext>
|
||||
|
||||
is up to 32 characters of text that can be displayed in the
|
||||
timestamp that is added to images. The 'show' action is designed to
|
||||
update this text without affecting alarms but the text is updated, if
|
||||
present, for any of the actions. This is designed to allow external input
|
||||
to appear on the images captured, for instance temperature or personnel
|
||||
identity etc.
|
||||
|
||||
=back
|
||||
|
||||
Note that multiple messages can be sent at once and should be LF or CRLF
|
||||
delimited. This script is not necessarily intended to be a solution in
|
||||
itself, but is intended to be used as 'glue' to help ZoneMinder interface
|
||||
with other systems. It will almost certainly require some customisation
|
||||
before you can make any use of it. If all you want to do is generate alarms
|
||||
from external sources then using the ZoneMinder::SharedMem perl module is
|
||||
likely to be easier.
|
||||
|
||||
=head1 EXAMPLES
|
||||
|
||||
3|on+10|1|motion|text|showtext
|
||||
|
||||
Triggers "alarm" on camera #3 for 10 seconds with score=1, cause="motion".
|
||||
|
||||
=cut
|
||||