@ -28,7 +28,82 @@ zmtrigger.pl - ZoneMinder External Trigger Script
=head1 DESCRIPTION
This script is used to trigger and cancel alarms from external connections
using an arbitrary text based format
using an arbitrary text based format.
This script offers generic solution to external triggering of alarms. It
can handle external connections via either internet socket, unix socket or
file/device interfaces. You can either use it 'as is' if you can interface
with the existing format, or override connections and channels to customise
it to your needs.
If enabled by the OPT_TRIGGERS option, Zoneminder service start
zmtrigger.pl which listens for control messages on TCP port 6802.
=head1 TRIGGER MESSAGE FORMAT
B<id>|B<action>|B<score>|B<cause>|B<text>|B<showtext>
=over 4
=item B<id>
is the id number or name of the ZM monitor.
=item B<action>
Valid actions are 'on', 'off', 'cancel' or 'show' where
'on' forces an alarm condition on;
'off' forces an alarm condition off;
'cancel' negates the previous 'on' or 'off'.
The 'show' action merely updates some auxiliary text which can optionally
be displayed in the images captured by the monitor. Ordinarily you would
use 'on' and 'cancel', 'off' would tend to be used to suppress motion
based events. Additionally 'on' and 'off' can take an additional time
offset, e.g. on+20 which automatically 'cancel's the previous action
after that number of seconds.
=item B<score>
is the score given to the alarm, usually to indicate it's
importance. For 'on' triggers it should be non-zero, otherwise it should
be zero.
=item B<cause>
is a 32 char max string indicating the reason for, or source of
the alarm e.g. 'Relay 1 open'. This is saved in the 'Cause' field of the
event. Ignored for 'off' or 'cancel' messages.
=item B<text>
is a 256 char max additional info field, which is saved in the
'Description' field of an event. Ignored for 'off' or 'cancel' messages.
=item B<showtext>
is up to 32 characters of text that can be displayed in the
timestamp that is added to images. The 'show' action is designed to
update this text without affecting alarms but the text is updated, if
present, for any of the actions. This is designed to allow external input
to appear on the images captured, for instance temperature or personnel
identity etc.
=back
Note that multiple messages can be sent at once and should be LF or CRLF
delimited. This script is not necessarily intended to be a solution in
itself, but is intended to be used as 'glue' to help ZoneMinder interface
with other systems. It will almost certainly require some customisation
before you can make any use of it. If all you want to do is generate alarms
from external sources then using the ZoneMinder::SharedMem perl module is
likely to be easier.
=head1 EXAMPLES
3|on+10|1|motion|text|showtext
Triggers "alarm" on camera #3 for 10 seconds with score=1, cause="motion".
=cut