fix OPTIONS_CAPTURING

This commit is contained in:
Isaac Connor 2022-01-11 10:44:42 -05:00
parent 52aed5b0bf
commit c97db738a3
1 changed files with 7 additions and 7 deletions

View File

@ -1102,16 +1102,16 @@ $OLANG = array(
certainly not what you want! To unlink monitors you can ctrl-click.
'
),
'CAPTURING' => array(
'Help' => 'When to do capturing:
None: Do not run a process, do not do capturing. Equivalent to the old Function == None
Ondemand: A zmc process will run, but will wait for a viewer (live view, thumbnail or rstp server connection) before connecting to the camera.
Always: A zmc process will run and immediately connect and stay connected.
'OPTIONS_CAPTURING' => array(
'Help' => 'When to do capturing:~~~~
None: Do not run a process, do not do capturing. Equivalent to the old Function == None~~~~
Ondemand: A zmc process will run, but will wait for a viewer (live view, thumbnail or rstp server connection) before connecting to the camera.~~~~
Always: A zmc process will run and immediately connect and stay connected.~~~~
',
),
'FUNCTION_ANALYSIS_ENABLED' => array(
'Help' => '
When in Modect, Mocord, Nodect or RECORD mode the analysis process can be turned on/off.
When to perform motion detection on the captured video.
This setting sets the default state when the process starts up.
It can then be turned on/off through external triggers zmtrigger zmu or the web ui.
When not enabled no motion detection or linked monitor checking will be performed and
@ -1120,7 +1120,7 @@ Always: A zmc process will run and immediately connect and stay connected.
),
'FUNCTION_DECODING_ENABLED' => array(
'Help' => '
When in Record or Nodect mode and using H264Passthrough with no jpegs being saved, we can
When not performing motion detection and using H264Passthrough with no jpegs being saved, we can
optionally choose to not decode the H264/H265 packets. This will drastically reduce cpu use
but will make live view unavailable for this monitor.'
),